AMERITONE PAINT CORP -- APF INTERIOR/EXTERIOR FLAT VINYL LATEX, PA7 -- 8010-00N017450
===================== Product Identification =====================
Product ID:APF INTERIOR/EXTERIOR FLAT VINYL LATEX, PA7
MSDS Date:11/19/1987
FSC:8010
NIIN:00N017450
=== Responsible Party ===
Company Name:AMERITONE PAINT CORP
Address:18414 SOUTH SANTA FE AVE
City:COMPTON
State:CA
ZIP:90221
Country:US
Info Phone Num:213-639-6791
Emergency Phone Num:213-639-6791
CAGE:FO133
=== Contractor Identification ===
Company Name:AMERITONE COATING CORP
Box:City:LONG BEACH
State:CA
ZIP:90801
Country:US
Phone:310-639-6791
CAGE:97903
Company Name:AMERITONE PAINT CORP/COMPTON, CA 90221
Box:190
CAGE:FO133
============= Composition/Information on Ingredients =============
Ingred Name:ING 8: IN CONFINED AREAS. WEAR NIOSH/MSHA APPRVD AIR SUPPLY
RESP/HOODS. USE NIOSH/MSHA APPRVD RESPIRATORS WHEN (ING 10)
RTECS #:9999999ZZ
Ingred Name:ING 9: FLAME CUTTING/WELDING/BRAZING & SANDING MATL COATED
W/PROD.
RTECS #:9999999ZZ
Ingred Name:VENT: BELOW CURRENT APPLICABLE SAFETY AND HEALTH STANDARDS
IN THE MIXING, APPLICATION AND CURING AREAS, AND (ING 12)
RTECS #:9999999ZZ
Ingred Name:ING 11: TO REMOVE SANDING DUSTS OF DRIED COATING & DECOMP
PROD DURING WELDING & FLAME CUTTING ON SURFACES COATED W/PROD.
RTECS #:9999999ZZ
Ingred Name:ETHYLENE GLYCOL (SARA III)
CAS:107-21-1
RTECS #:KW2975000
Fraction by Wt: < 5%
OSHA PEL:C 50 PPM
ACGIH TLV:C 50 PPM,VAPOR; 9192
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Ingred Name:PHENYLMERCURIC ACETATE (SARA III)
CAS:62-38-4
RTECS #:OV6475000
Fraction by Wt: < 1%
OSHA PEL:0.1 MG HG/M3;CEIL;S
ACGIH TLV:0.01 MG HG/M3; 9192
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Ingred Name:ESTER ALCOHOL; VP: 1 @ 87 C; LEL: 0.62 %
CAS:25265-67-7
Fraction by Wt: < 5%
Ingred Name:TITANIUM DIOXIDE
CAS:13463-67-7
RTECS #:XR2275000
Fraction by Wt: <5.0-15%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST; 9293
Ingred Name:AMMONIUM HYDROXIDE (SARA III)
CAS:1336-21-6
RTECS #:BQ9625000
Fraction by Wt: < 1%
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:CALCIUM CARBONATE (MARBLE) (LIMESTONE)
CAS:1317-65-3
RTECS #:EV9580000
Fraction by Wt: 10-15%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST; 9192
Ingred Name:ALUMINUM SILICATE
CAS:1302-93-8
Fraction by Wt: 15-20%
Ingred Name:SUPP DATA: MSHA APPROVED CHEM/MECH FILTERS DESIGNED TO
REMOVE A COMBINATION OF PARTICULATES AND VAPOR. WHEN USED(ING 9)
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: IRRITATION OF THE
RESPIRATORY TRACT: HEADACHE, NAUSEA, DIZZINESS. SKIN OR EYE
CONTACT: PRIMARY IRRITATION. CHRONIC: PROLONGED AND REPEATED
BREATHING OF SPRAY MIST AND/OR SANDING DUST OVE R A PERIOD OF YEARS
MAY CAUSE DUST DISEASE OF THE LUNGS.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE WHEN USED IN ACCORDANCE WITH
SAFE HANDLING AND USE INFORMATION.
======================= First Aid Measures =======================
First Aid:INHAL: REMOVE TO FRESH AIR. EYES: FLUSH IMMEDIATELY WITH
LARGE AMOUNTS OF WATER FOR AT LEAST 15 MIN. CONSULT A PHYSICIAN FOR
MEDICAL TREATMENT. SKIN: REMOVE WITH SOAP AND WATER. REMOVE SOILED
CLOTHING . INGEST: DRINK 1 OR 2 GLASSES OF WATERTO DILUTE. DO NOT
INDUCE VOMITING. CONSULT PHYSICIAN IMMEDIATLEY. TREAT
SYMPTOMATICALLY.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Lower Limits:SEE INGRED
Extinguishing Media:USE CO*2, DRY CHEM, FOAM OR OTHER NATIONAL FIRE
PROT ASSOCIATION (NFPA) APPRVD METHOD FOR TREATING CLASS B FIRES.
Fire Fighting Procedures:SUMMON PROF FIREFIGHT. WEAR NIOSH/MSHA
APPROVED SCBA AND FULL PROT EQUIP . H*2O SPRAY MAY BE INEFT. IF
H*2O IS USED. FOG NOZZLES ARE PREF. (SUPP DATA)
Unusual Fire/Explosion Hazard:DUE TO PRESS BUILD-UP, CLSD CNTNRS EXP TO
EXTREME HEAT MAY EXPLO. DURING EMERGENCY CNDTN, OVEREXP TO DECOMP
PROD MAY CAUSE HLTH HAZ. SYMP MAY NOT BE (SUPPDATA)
================== Accidental Release Measures ==================
Spill Release Procedures:WASH WITH WATER. BEFORE ATTEMPTING CLEAN-UP.
REFER TO HAZ CAUTION INFORMATION IN OTHER SECTIONS OF THIS MATERIAL
SAFETY DATA FORM. CONTAIN SPILLED MATERIAL AND REMOVE WITH
ABSORBENT. STORE IN CLOSED C ONTAINER UNTIL PROPELY DISPOSED OF.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE BELOW 110 F AND KEEP FROM
FREEZING. KEEP CONTAINER CLOSED WHEN NOT IN USE. DO NOT REUSE EMPTY
CONTAINERS.
Other Precautions:DO NOT TRANSFER CONTENTS TO BOTTLES OR OTHER
UNLABELED CONTAINERS. KEEP OUT OF REACH OF CHILDREN. USE ONLY WITH
ADEQUATE VENTILATION. DO NOT BREATHE VAPORS, SPRAY MISTS OR SANDING
DUST.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WHEN SPRAY APPLIED IN OUTDOOR OR OPEN AREAS WITH
UNRESTRICTED VENTILATION, AND DURING SANDING OR GRINDING
OPERATIONS, USE NIOSH/MSHA APPROVED MECH FILTER RESP TO REMOVE
SOLID (SUPP DATA)
Ventilation:PROVIDE GENERAL DILUTION OR LOCAL EXHAUST VENTILATION IN
VOLUME AND PATTERN TO KEEP AIR CONTAMINATION CONC (ING 11)
Protective Gloves:NOT REQUIRED.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE REQUIRED
Work Hygienic Practices:REMOVE AND WASH SOILED CLOTHING BEFORE REUSE.
WASH HANDS BEFORE EATING, SMOKING OR USING THE WASHROOM.
Supplemental Safety and Health
FIRE FIGHT PROC: IF EXPOSED TO FIRE OR EXTREME HEAT, H*2O SHOULD BE
USED TO COOL CLOSED CONTAINERS & PREVENT PRESS BUILD-UP OR POSSIBLE
AUTO IGNITION. EXPLO HAZ: IMMEDIATELY APPARENT. GET MEDICAL ATTE
NTION. RESP PROT: AIRBORNE PARTICLES OFOVERSPRAY AND SANDING DUST.
FOR RESTRICTED VENT AREAS, WEAR NIOSH/ (ING 8)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:69-72
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY CAUSE HAZARDOUS FUMES WHEN HEATED
TO DECOMPOSITION. FUMES MAY CONTAIN CO, CO*2, AND OXIDES OF
NITROGEN.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. INCINERATE ONLY IN APPROVED FACILITY. DO NOT
INCINERATE CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.